Connencted with thermocouples, the electromagnets are used as sefety devices built in various gas cocks, gas valves, grill devices and water boilers.
Thermocouple
Connected to safety gas valves and gas cocks, the thermocouples act as temperature sensors.
Remote thermometers
This device is adapted for temperature measurements in gaseous or liquid media, in industrial environment. Measurements are based upon thermal dilatation of the filled-in liquid. Areas of application: – small size boilers – hot water storage tanks The copper sensor element makes it unsuitable for measurements in aggressive environment.
Gas valve temperature sensors
Together with the internal elements of the gas valve, these sensors control the gas stream proportionally to the temperature. Temperature range: 10 – 35 °C 40 – 83 °C Areas of application: – gas stream regulation of convectors – gas stream regulation of boilers Trouble-free operation is conditioned by proper heat transfer between the controlled […]
Room temperature controllers
As the room temperature exceeds the set threshold value, the controller switches off the circuit. Switching-on takes place as soon as the room temperature falls below the set threshold value. This way, the room temperature is kept at a pre-selected constant value. The device is adapted for the following functions: temperature regulation: – in rooms, […]
Three-pole temparature limiters
These devices automatically switch off the current in the controlled circuit as the pre-set temperature limit is reached, thus preventing overheating. Once the problem related to temperature regulation is resolved, in voltage-free state, the limiter / protective guard can be re-started manually. Working temperature range: 0 – 355 °C Areas of application: – […]
Double-pole temparature limiters
These devices automatically switch off the current in the controlled circuit as the pre-set temperature limit is reached, thus preventing overheating. Once the problem related to temperature regulation is resolved, in voltage-free state, the limiter / protective guard can be re-started manually. Working temperature range: 0- 355 °C Areas of application: – […]
Single-pole temparature limiters
These devices automatically switch off the current in the controlled circuit as the pre-set temperature limit is surpassed, thus preventing overheating. Once the problem related to temperature regulation is resolved, in voltage-free state, the limiter can be re-started manually. Working temperature range: 0 – 355 °C Areas of application: – water heaters […]
Three-pole temperature controller
These devices automatically switch off the current in the controlled circuit as the pre-set temperature is reached, and switch on again as the temperature falls below the set threshold value. The temperature of the controlled medium is thus maintained within a narrow zone. Working temperature range: 0 – 355 °C Areas of application: […]
Double-pole temperature controller
These devices automatically switch off the current in the controlled circuit as the temperature is reached, and switch on again as the temperature falls below the set threshold value. The temperature of the controlled medium is thus maintained within a narrow zone. Working temperature range: 0 – 355 °C Areas of […]